نوع العمل : عمل كلى
الخبرة : 5-8 سنة
الراتب : Not Mentioned
المكان : Saudi Arabia
الخبرة : 5-8 سنة
الراتب : Not Mentioned
المكان : Saudi Arabia
Job Details
Experience Needed:5 To 6 YearsCareer Level:Experienced (Non-Manager)Education Level:Not SpecifiedSalary:ConfidentialJob Categories:
Experience Needed:5 To 6 Years
Career Level:Experienced (Non-Manager)
Education Level:Not Specified
Salary:Confidential
Job Categories:
Skills And Tools:
Job Description
Key Responsibilities
- Install, configure, and test PMUs, PDCs, GPS clocks, time synchronization systems, and network components.
- Perform site acceptance testing (SAT), end-to-end testing, and communication checks.
- Validate synchrophasor data quality, timestamps, and C37.118 compliance.
- Coordinate with substation teams, control centers, and OEM vendors during commissioning.
- Integrate PMUs and PDCs with SCADA/EMS systems, WAMS servers, and analytics platforms.
- Configure communication interfaces such as IEC 61850, DNP3, ICCP, and IEEE C37.118.
- Work with control center engineers to ensure seamless data flow and low-latency performance.
- Diagnose issues related to network communication, time-sync failures (GPS/NTP/PTP), and device configuration.
- Perform root-cause analysis of data freeze, bad quality data, packet drops, or incorrect phasor measurements.
- Assist utility clients in resolving field issues and coordinating with OEM support.
- Prepare commissioning reports, test sheets, as-built documents, and configuration backups.
- Maintain detailed installation records, network diagrams, and configuration logs.
- Provide technical inputs for FAT/SAT checklists and commissioning procedures.
- Ensure commissioning practices comply with cybersecurity standards (IEC 62443, IEC 62351, NERC CIP).
- Implement secure communication, VLAN segmentation, and role-based access for devices.
- Follow safety, regulatory, and utility-specific guidelines during fieldwork.
- Provide on-site and remote support to operations teams after commissioning.
- Conduct user training on PMU, PDC operation, troubleshooting, and WAMS dashboards.
- Support post-commissioning data validation and stabilization activities.
Key Responsibilities
- Install, configure, and test PMUs, PDCs, GPS clocks, time synchronization systems, and network components.
- Perform site acceptance testing (SAT), end-to-end testing, and communication checks.
- Validate synchrophasor data quality, timestamps, and C37.118 compliance.
- Coordinate with substation teams, control centers, and OEM vendors during commissioning.
- Integrate PMUs and PDCs with SCADA/EMS systems, WAMS servers, and analytics platforms.
- Configure communication interfaces such as IEC 61850, DNP3, ICCP, and IEEE C37.118.
- Work with control center engineers to ensure seamless data flow and low-latency performance.
- Diagnose issues related to network communication, time-sync failures (GPS/NTP/PTP), and device configuration.
- Perform root-cause analysis of data freeze, bad quality data, packet drops, or incorrect phasor measurements.
- Assist utility clients in resolving field issues and coordinating with OEM support.
- Prepare commissioning reports, test sheets, as-built documents, and configuration backups.
- Maintain detailed installation records, network diagrams, and configuration logs.
- Provide technical inputs for FAT/SAT checklists and commissioning procedures.
- Ensure commissioning practices comply with cybersecurity standards (IEC 62443, IEC 62351, NERC CIP).
- Implement secure communication, VLAN segmentation, and role-based access for devices.
- Follow safety, regulatory, and utility-specific guidelines during fieldwork.
- Provide on-site and remote support to operations teams after commissioning.
- Conduct user training on PMU, PDC operation, troubleshooting, and WAMS dashboards.
- Support post-commissioning data validation and stabilization activities.
Job Requirements
Required Skills & Experience
- B.E./B.Tech in Electrical Engineering, Electronics, Instrumentation, Power Systems (Preferred), or related fields.
- Min. of 5 - 6 years of Experience
- Hands-on experience with PMUs, phasor data concentrators (PDCs), µPMUs, and GPS time-sync devices.
- Strong understanding of synchrophasor technology, phasor concepts, and dynamic grid behavior.
- Good knowledge of communication protocols: IEEE C37.118, IEC 61850, DNP3, Modbus, ICCP/TASE.2
- Experience with network devices (switches/routers/firewalls) and industrial Ethernet.
- Familiarity with SCADA/EMS integration and real-time data acquisition systems.
- Experience with OEM devices (SEL, GE, Siemens, ABB, Arbiter).
- Ability to read electrical drawings, SLDs, wiring diagrams, and network architecture.
- Understanding of cybersecurity concepts, DMZ zones, firewall rules, ACLs, VLANs.
- Knowledge of oscillography, event analysis, and power system disturbance interpretation.
- Ability to work in substations, control centres, and remote field locations.
- Willingness to travel across regions for commissioning activities.
للتقديم الان
Required Skills & Experience
- B.E./B.Tech in Electrical Engineering, Electronics, Instrumentation, Power Systems (Preferred), or related fields.
- Min. of 5 - 6 years of Experience
- Hands-on experience with PMUs, phasor data concentrators (PDCs), µPMUs, and GPS time-sync devices.
- Strong understanding of synchrophasor technology, phasor concepts, and dynamic grid behavior.
- Good knowledge of communication protocols: IEEE C37.118, IEC 61850, DNP3, Modbus, ICCP/TASE.2
- Experience with network devices (switches/routers/firewalls) and industrial Ethernet.
- Familiarity with SCADA/EMS integration and real-time data acquisition systems.
- Experience with OEM devices (SEL, GE, Siemens, ABB, Arbiter).
- Ability to read electrical drawings, SLDs, wiring diagrams, and network architecture.
- Understanding of cybersecurity concepts, DMZ zones, firewall rules, ACLs, VLANs.
- Knowledge of oscillography, event analysis, and power system disturbance interpretation.
- Ability to work in substations, control centres, and remote field locations.
- Willingness to travel across regions for commissioning activities.